Can IPC Testing be Avoided?
On the whole ‘no’ but Process Analytical Technology (PAT) may replace some traditional IPC testing if technology is available (eg spectroscopy for reaction end point monitoring) PAT offers the potential to increase quality by o Improved process control by real time monitoring o Reduced testing of intermediates and maybe API Debate by no means finalised so IPC testing will be with us for years to come
27
27
3.2.S.2.5 Process Validation In-process testing is not the answer to all control strategies CHMP/QWP/130/96, 3.2.S.2.5 states
Steps that are identified in 3.2.S.2.4 as critical for the quality of the active substance should be validated, eg o Mixing of multiple components o Control of temperature and pH are critical o Addition of significant structural elements o Final purification step PV data for chemical DS not normally included in dossier according to ICH Q11(7.1)
28
28